| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-321-9404 Item Description: Circuit Breaker | 5925 | 013219404 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| Bda36050 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AKPX | POLE QUANTITY | 3 |
| CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40 0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| FREQ | FREQUENCY IN HERTZ | 60 0 ALL LOCATIONS |
| AJEC | BOSS HEIGHT | 0 190 INCHES NOMINAL |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 CLIP AND 3 TERMINAL |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CWJK | CASE MATERIAL | PLASTIC |
| ADAQ | BODY LENGTH | 6 000 INCHES NOMINAL |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 5 130 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 5 130 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1 500 INCHES NOMINAL |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 480 0 AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 18000 0 AC ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125 0 ALL LOCATIONS |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| TTQY | TERMINAL TYPE AND QUANTITY | 3 COMPRESSION AND 3 BUS BAR |
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| ADAT | BODY WIDTH | 4 500 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 3 160 INCHES NOMINAL |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1 500 INCHES NOMINAL |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50 0 AMPERES AC ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
Warrantied inventory at competitive prices
Search the world's largest inventory of electronic components by manufacturer, category or part number
All inventory ready to ship from our sellers
We sell only warrantied and traceable parts
Semiconductor's Certifications and Memberships
We are most trusted and leading distributor for aviation parts. You can get a quote within 15 minutes for your desired part. Quote Now!
Request for Quote